HFT

Hydro-Flo Technologies, Inc.

The Art and Science... of Wastewater Treatment

A "Green" company
 since 1990

                   

HFT HOME

Hydro-Flo Technologies, Inc

Products

Chemical Reaction Systems
Batch Treatment

pH Adjustment Systems

pH Neutralization Systems

Sequential Multi-Process
  Batch Treatment Systems

Chemical Reaction Systems
Continuous Flow

pH Adjustment Systems

pH Neutralization Systems

Multi Stage Chemical
  Reaction Systems

Flash Mix & Flocculation
  Systems

Clarifiers

LS Series Inclined Plate
  (IPC) Clarifiers

ClariMax Inclined Plate
  (IPC) Clarifiers

Control Panels

Relay Logic Based Panels

UL 508A

UL 698A (Intrinsically Safe)

Explosion Proof

PLC Systems

HMI Programming

SCADA Systems

Wireless Technology

Data Logging

Standards Compliance

Flotation Systems

Dissolved Air Flotation (DAF)

Media Filters

Deep Bed Sand

High Rate Sand

Multi-Media

Oil Water Separators

API

Enhanced Gravity Separators

Pressure Rated

Media Packs

DynaPac Cross Corrugated
  Coalescing Media

Packaged Systems

Typical Applications

Pump Packges

Electric Pump Packages

Pneumatic Pump Packages

HFT....

About Us

Company Profile

Customer List

Contact Us

Phone, E-mail, Fax, Etc...

Why Choose
Hydro-Flo Technologies

Request a Quote

E-Mail this page

E-Mail Us

 

 

Engineering Tools

Typical Applications

Follow this link to our library of application P&ID's and process descriptions

Application Questionnaire

Follow this link to our equipment application questionnaire

Clarifier Sizing information

Plate Settler Theory of Operation

Clarifier Settling / Cross Sectional Velocity Calculations

Test for Determination of Clarifier Hydraulic Loading Ratio

Clarifier Sizing Spreadsheet

Oil Water Separator Sizing information

Oil Water Separator Theory of Operation

Oil Water Separator Design Parameters

Test for Susceptibility of Separation of Oil from Water in a Gravity Type Oil/Water Separator

Enhanced Gravity (DynaPak, CPI, TPI, Parallel Plate) Type OWS Sizing Spreadsheet

API OWS Sizing Spreadsheet

Misc Info, Data, Spreadsheets & Calculations

EPA Non-Polar oil test methods

Fluid Mechanics

Reynolds Number Calculations

Water Hammer Calculations

HFT Quality Control

HFT Quality Assurance Plan

Steel Fabrications

Leak Test Certification

Interior Coatings

Exterior Coatings

Control Panels

Chemical / Material Compatibility Data

Chemical Pump Dosing Rates

Chemical Compatibility Chart

Properties of Plastic

Coating Data

Surface Prep Definitions

Hydro-Flo Technologies
Flotation Systems
Main Equipment Directory

Dissolved Air Flotation System, DAFHydro Flo Technologies flotation (DAF & IAF) systems are designed to accommodate flow rates as low as 10 gallon and as high as 3,000 gallons per minute.  The primary function of our flotation systems is to remove free and dispersed oils, emulsified oils along with dispersed suspended solids from wastewater or process water streams.  This makes it possible for sensitive downstream equipment to perform as designed.  A properly designed flotation (DAF) system will reduce the overall operating costs and improve overall system maintainability.

Dissolved Air Flotation System, DAFAs a separation device, flotation systems exhibit extremely high solids capture ratios, and will yield the highest level of recovered solids under a wide range of flow conditions. Oil/grease and suspended solids removal rates of greater than 95% are normal. Hydro-Flo has some customer applications reporting 99.9% O&G and SS removal. Because of there outstanding performance and reliability, Hydro-Flo flotation systems are the preferred process for a wide range of industrial water and wastewater treatment problems.

Dissolved Air Flotation
(DAF)

Dissolved Air Flotation
  System  Equipment Overview

Detailed Dissolved Air
  Flotation System Description

Induced Air Flotation
(IAF)

Induced Air Flotation          
  System Equipment Overview

Detailed Induced Air
  Flotation System Description


 

 


 

 

Dissolved Air Flotation System, DAF 01 Dissolved Air Flotation System, DAF 02 Dissolved Air Flotation System, DAF 03 Dissolved Air Flotation System, DAF 04 Dissolved Air Flotation System, DAF 05

Dissolved Air Flotation System, DAF 06 Dissolved Air Flotation System, DAF 07 Dissolved Air Flotation System, DAF 08 Dissolved Air Flotation System, DAF 09 Dissolved Air Flotation System, DAF 10

Dissolved Air Flotation System, DAF 11 Dissolved Air Flotation System, DAF 12 Dissolved Air Flotation System, DAF 13 Dissolved Air Flotation System, DAF 14 Dissolved Air Flotation System, DAF 15

Dissolved Air Flotation System, DAF 16 Dissolved Air Flotation System, DAF 17 Dissolved Air Flotation System, DAF 18 Dissolved Air Flotation System, DAF 19 Dissolved Air Flotation System, DAF 20

 

Chemical pretreatment for flotation systems:

Chemical pretreatment is not always needed with flotation systems. When used, chemical pretreatment allows for the separation and removal of contaminants a DAF or IAF alone will not remove.  Most pretreatment applications require the use of acids, caustics, coagulants and a flocculating polymers. The more common coagulants are inorganic salts such as alum, ferric chloride, ferrous sulfate, lime, sodium hydroxide or organic polymers. Preconditioning requirements are usually site specific and will impact operating cost, effluent quality, sludge volume and possibly water reuse.

The Hydro-Flo Technologies dissolved air flotation and induced air flotation systems can handle difficult wastewater applications as stand alone systems, or with any combination of chemical inputs including liquid polyelectrolyte's, dry powders, and organic and inorganic wastewater chemicals with various injection rates.

Hydro-Flo customers have the opportunity to utilize our wastewater tech resources located in St Charles, Illinois, USA. Instead of sending a grab sample (which may or not be truly representative) to our facility for analysis, we dispatch a chemist to your site in order to review your entire process.  Representative wastewater samples are taken and jar tests conducted on site to identify the most cost effective chemical pretreatment program.  A lab test study will also determine the most relevant equipment for your application.  Our on site lab tests also tell us the proper chemical treatment, proper mixing times, as well as present us with a good understanding of how and where to locate the chemical injection points in the piping system ahead of the flotation system. Lab studies identify approximate operating costs and wastewater cost savings. All this information is very valuable and necessary in order to develop the proper chemical regime and determine the proper sizing of the separation systems.

Contact Hydro-Flo today for details.

Wastewater Treatment Equipment